• About Dreisilker
  • Career Opportunities
  • Our Blog
  • Contact Us
  • Request a Quote
Call Dreisilker @ 630-469-7510
Dreisilker Electric Motors
  • Shop Online
  • Branch Locations
    • Illinois
      • Alsip
      • Chicago
      • Crystal Lake
      • Elk Grove Village
      • Glen Ellyn
    • Georgia
      • Marietta
    • Texas
      • Carrollton
  • Repair Services
    • Repair by Type
      • AC Motors
      • Blower Motors
      • Centrifugal Blower Motor Repair
      • Chiller Motor Repair
      • Compressor Motors
      • DC Motors
      • Foreign Motors
      • Gas Booster Repair
      • Gearboxes
      • Gear Motor Repair
      • Generators
      • Printing Press Motor Repair
      • Pumps
      • Servo Motors
      • UL Explosion Proof Motors
      • Vacuum Pumps
      • Wind Turbines
    • Repair Services
      • MotorSafe Repair Process
      • Advanced Varnishing
      • Commutator Repair
      • Machining Services
      • Rewinding Services
        • Armature Repair
        • Armature Rewinding
    • Repair by Industry
      • Heat Treating
      • Crane & Hoist
      • Manufacturing
      • Machine Tool
      • Printing
      • Plastics
      • Steel Mill
  • Field Services
    • Field Services
      • Dynamic Balancing
      • Electronics Repair
      • Infrared Inspection
      • Laser Shaft Alignment
      • Motor and Electronics Troubleshooting
      • Electric Motor Diagnostic Tests
      • Variable Frequency Drive Support
      • Vibration Analysis
    • Engineering Services
      • Electric Motor Contract Manufacturing
      • Complete Machine Shop
      • Balloon and Solid Shaft Repair
  • Motor and Drive Sales
    • All Brands
      • Century Electric Motors
      • CoolBLUE Inductive Absorbers
      • Fasco
      • Genteq
      • Lau
      • Leeson
      • Marathon Electric
      • Optibelt
      • Packard Electric Motors
      • Siemens
      • Yaskawa VFD
      • Teco Westinghouse

Basics of Variable Frequency Drives

June 21, 2018/1 Comment/in Aegis Shaft Grounding Rings, CoolBlue, Variable Frequency Drives /by Lynn Dreisilker

Variable Frequency Drives (VFDs) are used to adjust the speed of motors. There are many different names for VFDs including adjustable speed drive, adjustable frequency drive, AC drive, microdrive, and inverter drive. VFDs adjust the speed of motors by changing the frequency being transferred to the motor. For example, when the VFD is receiving power at 60 hz, it can change the frequency to 20 hz, resulting in a slower rotation of the motor.

The Different Parts of a Variable Frequency Drive:

The three parts of a VFD that allow the drives to change frequency are the converter, dc bus, and inverter sections.

  • Converter: AC power enters the VFD’s converter which converts the power from AC to DC power.
  • DC Bus: After it is converted, the power travels through the DC Bus.
  • Inverter: The power then enters the inverter section which is made up of small circuit board components called insulated gate bipolar transistors (IGBT). The IGBT act as triggers to take the dc power to spit out the dc power in short bursts, then flips the polarity. The IGBT continues spitting out the power in short bursts and flipping the polarity.

The outcome is Pulse Width Modulation (PWM) which is a simulated AC power at a specific frequency.

 

 

Variable Frequency Drive Diagram

 

Some benefits of using VFDs include:

  • Mechanical stress and belt wear on equipment is far less when using a drive versus across the line starting of a motor.
  • Motors running on drives are protected from incoming power surging and single phasing.
  • Reducing the speed of a motor by 20% will reduce the power consumption of a motor by 50%, calculated using the affinity law.
  • High efficiency at low speed
  • Speed Variation

Selecting and Installing the Right VFD

Choosing the correct VFD for your application is critical to getting optimal performance and long-term reliability. Factors like motor size, load type (variable or constant torque), environmental conditions, and control requirements all impact drive selection. Proper installation is equally important—ensuring the drive is wired correctly, configured for your motor, and protected from external factors like heat, dust, and vibration. At Dreisilker, we help customers every step of the way, from selecting the right drive to professional installation and troubleshooting support. Whether you’re managing the install yourself or need a full turnkey solution, our team is here to ensure your system runs efficiently and reliably.

field service drive install

What are the Different Torque Requirements?

There are two types of torque requirements found in VFD applications, including variable torque load and constant torque load. Variable torque loads are typically found in applications like fans, blowers, spinning compressors and spinning pumps which move easy loads such as air or (clean) liquid. The application requires more torque as you are moving more of the air or fluid. As the motor or pump speeds up, the amount of force required to move the load increases. The increase in the need of force is why they are considered variable torque loads.

Conversely, Constant Torque loads are found in the applications that require the same amount of torque to move the loads at slower and faster speeds. Common constant torque loads are found in conveyors, elevators, shredders and extruders.

Both types of torque loads need to be able to provide the application with their full load amps (fla) which is 100%. Variable torque loads can provide an application with low overload capability of 110% fla for instances when the load changes or if it encounters extra loads momentarily. Constant torque loads are designed to allow 150% fla which is considered high overload capability. The high and low overload capabilities allow for the application to handle the temporary overload without the motor shutting down.

Are there any downsides to VFDs?

Although VFDs allow for improved motor efficiencies, they also present a problem for motor bearing life. The VFDs can emit damaging currents that go to ground through a motor’s bearing. Eventually, this can lead to pitting, fluting, frosting of bearings, lubrication break down and overall destruction of the bearing. The harmful currents can be stopped by installing CoolBlue Inductive Absorbers and Aegis Grounding rings. To learn about these products, you can read our blogs CoolBlue Inductive Absorbers and Aegis Shaft Grounding Rings.

 

Aegis Shaft Grounding Rings Protect your Motors and Bearings

June 6, 2018/0 Comments/in Aegis Shaft Grounding Rings, CoolBlue, Electric Motor Protection, Variable Frequency Drives /by Lynn Dreisilker

Aegis Shaft Grounding Rings protects bearings and electric motors from damaging shaft voltages caused by variable frequency drives (VFDs). The voltages emitted by VFDs find their way to ground typically through the motor’s bearing. Some signs of these damaging currents include pitting, frosting, fluting and loss of bearing lubrication. Installing Aegis Shaft Grounding Rings to your motors can prevent bearing and motor failure caused by the shaft voltages.

The Aegis Shaft Grounding Rings work by diverting the damaging voltages away from the bearings by sending it to ground through the motor frame. The rings are made of conductive microfibers that encircle the motor shaft and is installed on the drive end of the motor. For motors 100HP and higher, it is recommended to use an insulated bearing on the non-drive end with the Aegis Ring installed on the drive end.

 

 Aegis Shaft Grounding Rings Kit
Aegis Shaft Grounding Ring Kit.
 Aegis Shaft Grounding Rings Diagram 2
Conductive Microfibers.
 Aegis Shaft Grounding Rings Diagram
Diagram of an Aegis Shaft Grounding Ring.

 

Even though a motor may be rated inverter duty, you need to keep in mind that this does not mean that it comes with grounding rings preinstalled. If you need an inverter duty motor with grounding rings pre-installed, you will need to select the option for grounding rings. Most motors now have the option to come with grounding rings preinstalled. If you already have a motor in the field that needs protection, you can order an Aegis Shaft Grounding kit and install it on your motor.

There are different types of Aegis Rings that allow for installation on many applications. They are available in solid and split-ring designs, configured for NEMA and IEC motors, and include four mounting bracket styles and hardware. The different types of Aegis Rings can be found in our online store. If you need assistance finding the proper Aegis Rings for your application, we are able to help you source the rings.

Whenever you have a motor with grounding rings installed, you should add visually examining the Aegis Rings to your preventative maintenance checklist. Like most parts of a motor operation, grounding rings can be negatively affected by contamination. While checking your motors, inspect the rings for any sign of contamination that can cause ineffectivity of the ring. Aegis now offers a 2 year warranty against fluted bearings when you register your rings with Aegis.

Although the Aegis Shaft Ground Rings are a trustworthy solution to protect your motors, it is not the only solution to prevent damaging currents emitted by VFDs. Another solution that we highly recommend you utilize in conjunction with the Aegis Rings is CoolBlue Inductive Absorbers. CoolBlue are common mode chokes that are installed by placing the CoolBlue rings around the motor’s lead wires. To learn more about CoolBlue and its benefits, read “How CoolBlue Protects Your Motors and Bearings.”

If you are utilizing VFDs in your operations, you should consider protecting your bearings from damaging currents through the use of Aegis Shaft Grounding Rings and CoolBlue.

How CoolBlue Protects Your Motors and Bearings

April 17, 2018/0 Comments/in CoolBlue, Electric Motor Protection, Variable Frequency Drives /by Lynn Dreisilker

CoolBlue Inductive Absorbers protect motors and bearings from high frequency currents caused by Variable Frequency Drives. Without CoolBlue, damaging currents emitted by variable frequency drives can lead to bearing damage and ultimately electric motor failure. Some types of bearing damage include pitting, fluting, frosting of bearings, lubrication break down and overall destruction of the bearing.

CoolBlue are inductive absorber rings that are installed on all three power phase lead wires between the variable frequency drive and the electric motor. Once installed, CoolBlue acts as a common mode choke that reduces transient voltages, stray capacitive currents and common mode currents before they reach the electric motor.

CoolBlue Application Diagram web

Installing CoolBlue in your variable frequency drive applications can prevent production downtime, additional maintenance, costly motor repair, and expensive bearing replacement. In addition to the benefits of protecting your bearings and motors, CoolBlue is easy to install, lasts the lifetime of your motor and is maintenance free.

Common applications for CoolBlue include:

  • OEM Manufacturers of HVAC Equipment
  • Paper/Bottling/Food/Chemical Manufacturing
  • Washdown Applications
  • Hospital, Office and Commercial Buildings
  • Automobile and Related Product Manufacturing
  • All Pump and Fan related applications
  • Wind, Solar and other renewable energy applications
  • All Variable Frequency Drive Applications

How to Select the Correct CoolBLUE products:

See our full blog on our CoolBLUE selection guide here: How to Select the Correct CoolBLUE for your Application

For more specialized motor applications that require higher reliability, Nanoperm Line Absorbers (NaLa) are recommended in addition to CoolBlue Inductive Absorbers. NaLa further reduces the variable frequency drive noise and peak values of current. Unlike CoolBlue, NaLa is installed on each of the power phase wires, not over all three power phases. NaLa is to be used in conjunction with CoolBlue to further increase the reliability and uptime of your motor system.

The CoolBlue and NaLa products are sized by HP and total cable length from the VFD to motor.  If there are two cables on each output leg then the distance needs to be multiplied by 2 or so on for each added cable per phase.  There are 4 popular sizes that are stocked that cover from 1/4HP to 400HP. When lead lengths are longer then 150ft, 300ft, 450ft, and 900ft, then more cores are added to the system. For more information on how to properly install CoolBlue, see this installation guide.

One major advantage of installing CoolBlue and NaLa is the reduced installation time needed over other options.  Also, there is no need for an insulated bearing on motors with over 100 HP. CoolBlue and NaLa are readily available at Dreisilker Electric Motors, Inc.

In addition to the usage of CoolBlue in VFD applications, you can also protect your motors with Aegis Shaft Grounding Rings. The Aegis Rings work by diverting the damaging voltages away from the bearings by sending it to ground through the motor frame. The rings are made of conductive microfibers that encircle the motor shaft and is installed on the drive end of the motor. To learn more about the Aegis rings, read our blog Aegis Shaft Grounding Rings Protect your Motors and Bearings.

 

Request a Quote for CoolBlue

Request a Quote

Post Categories

  • Aegis Shaft Grounding Rings
  • Bearings
  • Belts
  • Brushes
  • Company News
  • Condenser
  • CoolBlue
  • Cooling Season
  • DC Motors
  • Efficiency
  • Electric Motor Protection
  • Electric Motors
  • Fan Blades
  • Field Services
  • Heating Season
  • Infrared Inspection
  • Motor Repair
  • Motor Starters
  • News
  • Overload Relays
  • Predictive Maintenance
  • Reliability Services
  • Servo Motors
  • Uncategorized
  • Variable Frequency Drives

Dreisilker Information

  • About Dreisilker
  • Career Opportunities
  • Our Blog
  • Contact Us
  • Request a Quote

Quick Links

  • Branch Locations
  • Repair Services
  • Reliability and Field Services

STAY UP TO DATE –

Sign up for our newsletter:

 

Scroll to top